TOP IMPLART AT 152 MeV: SPOT SCANNING AFTER BEAM-1 LINE <- L1-><-d-><-L2-><----------L----------> M1 M2 Tentative parameters: L1=0.2 m L2=0.4 m d=0.2 m L=1.5 m Bmax=0.3 T 8 Aprile 2010 C. RONSIVALLE BEAM-1 LINE (Current design) Lquad=180 mm 1.6 m 0.6 m Beam at the entrance of scanning magnet 1 Horizontal size (FWHM)=8.7 mm Vertical size (FWHM)=9.08 mm Max. x-displacement due to hor. kick given by M1 M1 and M2 are approximated as two steerers placed in the middle of the magnets. Each particle gets a kick depending on its energy Beam at the output of scanning magnet 2 Bx vs t for one row scanning time=100 msec IRRADIATED FIELD: 100x100 mm One row, nsteps=10 Step length=1 FWHM F=100 Hz Hor. centroids displacement IRRADIATED FIELD: 100x100 mm One row, nsteps=10, Step length=1 FWHM F=100 Hz IRRADIATED FIELD: 100x100 mm One row, nsteps=20 Step length=FWHM/2 F=200 Hz EXAMPLES OF SCANNING MAGNETS 1. CNAO 1. CNAO 2. INDIANA UNIVERSITY CYCLOTRON FACILITYBLOOMINGTON 2. INDIANA UNIVERSITY CYCLOTRON FACILITY-BLOOMINGTON 3. GSI