Service RinNOVA NOX -------------------------------------------------------------------------------------------------------- CIRCUITO COMANDO NUOVO PANNELLO COMANDO Service Impostazione temperatura sanitaria Selettore stagionale e reset caldaia Impostazione temperatura riscaldamento RINNOVA NOX PANNELLO COMANDO Service • VISUALIZZAZIONE DISPLAY RINNOVA NOX SCHEDA COMANDO BERTELLI • Service SCHEDA B&P COD. 14064.1224.0; RINNOVA NOX SCHEMA ELETTRICO CAMERA STAGNA Service RINNOVA NOX COLLEGAMENTI ELETTRICI Service • COLLEGAMENTO ALIMENTAZIONE ELETTRICA – RISPETTARE FASE E NEUTRO – NON SENSIBILE AD INVERSIONE DI FASE RINNOVA NOX COLLEGAMENTI ELETTRICI Service • COLLEGAMENTO TERMOSTATO AMBIENTE – PER IL COLLEGAMENTO DEL TERMOSTATO AMBIENTE SERVISRSI DEI MORSETTI A e B. – ATTENZIONE L’INSTALLAZIONE DEL TERMOSTATO AMBIENTE ESCLUDE QUELLA DEL COMANDO REMOTO RINNOVA NOX FUNZIONAMENTO CON GESTIONE SOLARE Service • GESTIONE SOLARE – LA SCHEDA E’ COMPATIBILE PER ESSERE INTERFACCIATA CON SCHEDA SOLARE BIASI. – LA SCHEDA SOLARE VIENE INTERFACCIATA SULLA LINEA COMANDO REMOTO. – IL DISPLAY DELLA CALDAIA INDICHERA’ LO STATO DI FUNZIONAMENTO DELL’IMPIANTO SOLARE; – LA SCHEDA SOLARE VA CONFIGURATA IMPOSTANDO I SEGUENTI PARAMETRI: – 26,27 PER CONFIGURAZIONE SCHEMA IDRAULICO; – 25 PER DIALOGO CON CALDAIA IMPOSTANDO VALORE 3; – INTERFACCIARE LA CENTRALINA SOLARE SULLA LINEA T.A; – CONFIGURARE IL PARAMETRO 3 DELLA SCHEDA COMANDO COME SONDA NTC (BOLLITORE INTERNO); – IN QUESTO CASO LA TEMPERATURA BOLLITORE SARA’ LA TEMPERATURA DEL BOLLITORE RILEVATA DALLA SONDA S1 RINNOVA NOX COMANDO Service • SCHEDA INTEGRATA FUNZIONI • FUNZIONI NORMALI – MODULAZIONE RISCALDAMENTO – MODULAZIONE SANITARIA – FUNZIONE ANTIGELO – FUNZIONE 24 ORE – SICUREZZA ASSENZA PRESSIONE – GESTIONE VERIFICA CIRCOLAZIONE ACQUA – POST CIRCOLAZIONE SANITARIA – SISTEMA GESTIONE SONDE DI TEMPERATURA – FUNZIONE POSTVENTILAZIONE – (SISTEMA PRERISCALDO 3 STELLE) – MENU’ HISTORY • FUNZIONI PARTICOLARI – GESTIONE PROGRAMMAZIONE PARAMETRI RINNOVA NOX MODULAZIONE RISCALDAMENTO Service • MODALITA’ • PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA DI MANDATA DEL CIRCUITO RISCALDAMENTO SELEZIONATA TRAMITE I TASTI DI REGOLAZIONE RISCALDAMENTO (13)e (14) O COMANDO REMOTO E CONTROLLATA DAL NTC. RINNOVA NOX MODULAZIONE SANITARIO Service • MODALITA’ • PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA DI ACQUA CALDA SANITARIA SELEZIONATA TRAMITE I TASTI DI REGOLAZIONE SANITARIO (10) e (11) O COMANDO REMOTO E CONTROLLATA DALLA SONDA NTC. RINNOVA NOX FUNZIONI ANTIGELO E 24H Service • FUNZIONE ANTIGELO – FUNZIONE CHE SI ATTIVA QUANDO LA SONDA RISCALDAMENTO RILEVA UNA TEMPERATURA AL DI SOTTO DEI 5°C AZIONANDO LA POMPA ED IL BRUCIATORE ALLA MINIMA POTENZA FINO AL RAGGIUNGIMENTO DEI 35°C. – ON 5° – OFF 35° – FUNZIONE ATTIVA ANCHE CON SELETTORE IN OFF E IN ESTATE – NELL’EVENTUALITA’ DI MANCANZA GAS IL CIRCOLATORE RIMANE ALIMENTATO • FUNZIONE ANTIBLOCCAGGIO O 24H – FUNZIONE CHE SI ATTIVA QUALORA LA CALDAIA NON VENISSE UTILIZZATA PER UN LUNGO PERIODO. OGNI 24 ORE: – IL CIRCOLATORE SI ATTIVA PER 30 SECONDI – LA VALVOLA DEVIATRIECE VIENE FATTA COMMUTARE PER 10 sec. OGNI 24 ORE. – FUNZIONE ATTIVA ANCHE CON CALDAIA IN BLOCCO O SELETTORE IN STAND-BY RINNOVA NOX GESTIONE VERIFICA PRESSIONE Service • SICUREZZA ASSENZA PRESSIONE D’ACQUA • • FUNZIONE DI SICUREZZA CHE PERMETTE DI VERIFICARE LA PRESENZA E IL VALORE DI PRESSIONE DEL CIRCUITO IDRAULICO RISCALDAMENTO. VERIFICA PRESENZA ACQUA E VALORE DI PRESSIONE TRAMITE IL TRASDUTTORE DI PRESSIONE. – IL FUNZIONAMENTO DELLA CALDAIA VIENE IMPEDITO IN CASO DI: – MANCATO COLLEGAMENTO DEL TRASDUTTORE; – NEL CASO IN CUI VENGA MISURATA UNA PRESSIONE MINORE O UGUALE A 0,2 bar; – SE: – IL CONTATTO E’ INTERROTTO e/o NON SI CHIUDE – O IN CORTO CIRCUITO; – O IL TRASDUTTORE E’ DIFETTOSO; – MANCA PRESSIONE IN CALDAIA < 0,2 Bar. – TRAMITE IL DISPLAY DELLA CALDAIA COMPARE L’ERRORE DEDICATO 04 RINNOVA NOX GESTIONE ASSENZA CIRCOLAZIONE ACQUA Service • VERIFICA CIRCOLAZIONE ACQUA (NTC RISCALDAMENTO) – VIENE VERIFICATO CHE DOPO L’ACCENSIONE DEL BRUCIATORE VI SIA SCAMBIO TERMICO CON L’ACQUA CHE ATTRAVERSA LO SCAMBIATORE PRIMARIO. – FUNZIONE CHE VIENE GESTITA E CONTROLLATA DAL CIRCUITO INTEGRATO TRAMITE DUE CONTROLLI: – TRAMITE INNALZAMENTO DELLA TEMPERATURA LETTA DALLA SONDA NTC RISCALDAMENTO IN FASE DI ACCENSIONE (GRADIENTE) – LA FUNZIONE SI ATTIVA DOPO 12 Sec DALLA RICHIESTA – LA VARIAZIONE DI TEMPERTURA DEVE ESSERE INFERIORE A 6,5°C/Sec – PER SOVRATEMPERATURA IN FASE DI SPEGNIMENTO – LA TEMPERATURA NON DEVE SALIRE OLTRE I 15° RISPETTO A QUELLA DI SPEGNIMENTO RINNOVA NOX GESTIONE ASSENZA CIRCOLAZIONE ACQUA Service – PER ENTRAMBI I CONTROLLI QUALORA VI SIA UN’ ANOMALIA INIZIA FASE DI CONTEGGIO (5 VOLTE) AL TERMINE DELLA QUALE LA CALDAIA VA IN BLOCCO. DURANTE,LA POMPA RIMANE ALIMENTATA – IL BRUCIATORE SI RIACCENDE QUANDO LA TEMPERATURA SCENDE SOTTO I 43° – RESET CONTATORE OGNI 24h RINNOVA NOX POST CIRCOLAZIONE Service • IN SANITARIO – FUNZIONE CHE SI ATTIVA AL TERMINE DI UNA RICHIESTA SANITARIA PER OMOGENIZZARE LA TEMPERATURA DEL CIRCUITO PRIMARIO. – SI ATTIVA PER 10 SECONDI IL CIRCOLATORE, TALE TEMPO NON PUO’ ESSERE MODIFICATO. • IN RISCALDAMENTO – FUNZIONE CHE SI ATTIVA AL TERMINE DI UNA RICHIESTA RISCALDAMENTO DAL TERMOSTATO AMBIENTE – SI ATTIVA PER 3,6 MINUTI IL CIRCOLATORE, TALE TEMPO PUO’ ESSERE MODIFICATO TRAMITE IL PARAMETRO “P11” RINNOVA NOX GESTIONE SONDE (NTC) Service • FUNZIONE CHE PERMETTE DI VERIFICARE IL CORRETTO FUNZIONAMENTO DELLE SONDE DI TEMPERATURA – SE LA SONDA RISCALDAMENTO E’ INTEROTTA(>100KΩ) O IN CORTO CIRCUITO (<200Ω) LA CALDAIA VIENE DISATTIVATA DA TUTTE LE SUE FUNZIONI – SE LA SONDA SANITARIA E’ INTEROTTA (>100KΩ) O IN CORTO CIRCUITO (<200Ω) LA CALDAIA FUNZIONA REGOLARMENTE IN RISCALDAMENTO MENTRE IN SANITARIO: – LA TEMPERATURA VIENE GESTITA DALLA SONDA RISCALDAMENTO RINNOVA NOX DIAGNOSTICA TRAMITE LCD Service Pressione circuito Insufficiente Cablaggio EVG RINNOVA NOX FUNZIONI DISPLAY Service • VISUALIZZAZIONE MODALITA’ INFO TRAMITE LCD (1): – LA MODALITA’ INFO PERMETTE LA VISUALIZZAZIONE DI ALCUNE INFORMAZIONI SULLO STATO DI FUNZIONAMENTO DELLA CALDAIA. – PER ACCEDERE ALLA MODALITA’ INFO TENERE PREMUTI CONTEMPORANEAMENTE I TASTI (12) E (14) FINO A FAR APPARIRE SUL DISPLAY L’INDICE “J00” SEGUITO DAL VALORE DEL PARAMETRO “b - -” (ES: “b13”=1,3bar) – PER SCORRERE NELLA VISUALIZZAZIONE DELLE INFO PREMERE I TASTI (13) O (14) RINNOVA NOX VISUALIZZAZIONE PARAMETRI INFO Service • VISUALIZZAZIONE MODALITA’ INFO TRAMITE LCD (2): RINNOVA NOX MENU’ HISTORY Service • MENU’ HISTORY – LA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORI. – PER ACCEDERE ALLA MODALITA’ “HISTORY” PREMERE CONTEMPORANEAMENTE I TASTI 12 E 14; – NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO PROGRESSIVO DELL’ERRORE. – IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO. – TRAMITE I TASTI 10 E 11 SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI MEMORIZZATI. RINNOVA NOX Service Settaggio scheda ricambio SCHEDA COMANDO BERTELLI • • LA NUOVA SCHEDA COMANDO VA CONFIGURANTA TENENDO IN CONSIDERAZIONE SU CHE TIPOLOGIA DI CALDAIA VIENE INSTALLATA. LA CONFIGURAZIONE DELLA SCHEDA PUO’ ESSERE EFFETTUATA TRAMITE: – UTILIZZO PANNELLO COMANDI CALDAIA; – UTILIZZO COMANDO REMOTO. Service PROGRAMMAZIONI PARAMETRI • Service PROGRAMMAZIONE TRAMITE PANNELLO COMANDI CALDAIA (1): • PROCEDURA PER ENTRARE IN MODALITA’ PROGRAMMAZIONE: 1. 2. 3. 4. 5. PREMERE PER 10 sec.I TASTI 12 + 13 + 14 FINO A FAR APPARIRE NEL DISPLAY LCD, IL PRIMO PARAMETRO, “P01” CHE SI ALTERNA CON IL VALORE DEL PARAMETRO. PREMENDO I TASTI 13 E 14 SI SCORRONO I PARAMETRI. PREMENDO I TASTI 10 E 11 E’ POSSIBILE MODIFICARE IL VALORE DEL PARAMETRO. PREMENDO IL TASTO 12 SI CONFERMA IL VALORE DEL PARAMETRO. PER USCIRE PREMERE PER10 sec.I TASTI 12 + 13 + 14. RINNOVA NOX PROGRAMMAZIONE PARAMETRI Service • PROGRAMMAZIONE TRAMITE COMANDO REMOTO (2): – PREMERE IL TASTO IP FINO AD ENTRARE IN INFO – PREMERE INSIEME I TASTI PER ENTRARE IN PROGRAMMAZIONE – PREMERE I TASTI PER SCORRERE I PARAMETRI – PREMERE I TASTI PER MODIFICARE IL VALORE – LA MEMORIZZAZIONE AVVIENE IN AUTOMATICO DOPO POCHI SECONDI – PREMERE IP PER USCIRE RINNOVA NOX LISTA PARAMETRI Service RINNOVA NOX 1 – PARAMETRI Service PM DISPLAY LCD FUNZIONE SETTAGGIO DEFAULT PM01 P01 POTENZA CALDAIA 1 = 24 Kw 2 = 28 Kw Set di fabbrica PM02 P02 TIPOLOGIA CALDAIA COMBUSTIONE 0 = STAGNA FISSO NON MODIFICABILE Set di fabbrica PM03 P03 TIPOLOGIA CALDAIA SANITARIA 0 = RAPIDA SCAMBIATORE A PIASTRE 1 = RAPIDA SCAMBIATORE A PIASTRE 3 = BOLLITORE CON TERMOSTATO ON/OFF 4 = BOLLITORE CON SONDA NTC DA SOLARE Set di fabbrica PM05 P05 TIPO GAS 0…4 = METANO 5 = GPL 0 RINNOVA NOX 2 – PARAMETRI Service PM LCD DISPLAY FUNZIONE SETTAGGIO DEFAULT PM07 P07 CAMPO REG.RISC REGOLABILE TRA 45 - 85°C 85 PM08 P08 RIPRISTINO VALORI DEFAULT Ripristino = 4 Reset totale = 39 0 PM09 P09 FUNZIONE SPAZZACAMINO 0= nessuna attivazione 1 = min. potenza term. San 2 = min. potenza term. Risc 3 = max. potenza termica Risc 4 = max. potenza termica San 15= Taratura valvola gas 0 PM10 P10 RITARDO RIACCENSIONE RISCALDAMENTO 0 = 0 sec 100 = 500 sec = 8,3 min. 36 = 1,8 min PM11 P11 POSTCIRCOLAZIONE RISCALDAMENTO 0= 0 sec 100= 500 sec = 8,3 min. 12 = 1 min PM12 P12 POTENZA MAX RISC. 0 = 0% 100 = 100% 100 RINNOVA NOX 3 – PARAMETRI PM PM13 LCD DISPLAY Service FUNZIONE SETTAGGIO VALVOLA TRE VIE 0 = GRUPPO OTTONE DEFAULT 0 P13 2 = GRUPPO PLASTICA PM14 P14 POTENZA ACCENSIONE 0 = 0% 100 = 100% max PM15 P15 PM16 P16 PM17 P17 40% ABILITAZIONE SONDA ESTERNA 0 = non abilitata = 00 1= K 0,1 60= K 6 0 MINIMO RISCALDAMENTO 0 = 100 % 45 ATTIVAZIONE ANTILEGIONELLA 0 = ANTILEGIONELLA OFF; 1 = ANTILEGIONELLA ATTIVO OGNI 2 GIORNI; 2 = ANTILEGIONELLA ATTIVO OGNI 3 GIORNI; 0 RINNOVA NOX 4– PARAMETRI Service PM LCD DISPLAY FUNZIONE SETTAGGIO DEFAULT Da P18 a P24 P18….P24 NON GESTITO PM25 P25 VALORE MNIMO TARATURA VALVOLA GAS 0…….100 SOLA LETTURA PM26 P26 VALORE MASSIMO TARATURA VALVOLA GAS 0…….100 SOLA LETTURA PM27 P27 TEMPERATURA MINIMA SETPOINT RISCALDAMENTO 25…….45 38 PM28 P28 MESI MANUTENZIONE 0……..48 99 = OFF 12 -------- RINNOVA NOX 5– PARAMETRI Service PM LCD DISPLAY FUNZIONE SETTAGGIO PM29 P29 TEMPERATURA ACQUA INGRESSO 0…….45 °C DEFAULT 10 0 = OFF PM30 P30 PRESSIONE ACQUA IMPIANTO NOMINALE 5……20 B 10 PM31 P31 ATTIVAZIONE SCHEDA RELE’ (optional) 0 = NON ATTIVA 1 = ATTIVA 0 PM32 P32 ATTIVAZIONE SCHEDA RELE’ (optional) 0 = NON ATTIVA 1 = ATTIVA 0 RINNOVA NOX FUNZIONE SPAZZACAMINO • Service FUNZIONE CHE PERMETTE DI EFFETTUARE IN MODO VELOCE L’ANALISI DI COMBUSTIONE. – PROCEDURA PER ATTIVARE LA FUNZIONE: 1. ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI 12,13 E 14 FINO A FAR APPARIRE IL PARAMETRO “P01”; 2. PREMERE I TASTI 13 + 14 FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO “P09”; 3. TRAMITE I TASTI 10 + 11 IMPOSTARE IL VALORE RIFERITO ALLA POTENZA MASSIMA; 4. PREMERE IL TASTO 12 PER MEMORIZZARE IL VALORE IMPOSTATO E PROCEDERE ALLA VERIFICA DI COMBUSTIONE. RINNOVA NOX FREQUENZA DI RIACCENSIONE • Service PERMETTE DI REGOLARE IL TEMPO CHE DEVE INTECORRERE TRA UN’ACCENSIONE E L’ALTRA – LA PROCEDURA PER VARIARE L’IMPOSTAZIONE PREVEDE: 1. ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI 12,13 E 14 FINO A FAR APPARIRE IL PARAMETRO “P01”; 2. SCORRERE I PARAMETRI PREMENDO I TASTI 13 E 14 FINO A FAR APPARIRE SUL DISPLAY IL VALORE PARAMETRO “P10”; 3. UTILIZZANDO I TASTI 10 E 11 PER VARIARE IL VALORE DEL PARAMETRO: 4. RANGE DI IMPOSTAZIONI: – DA “00” = 0 sec a ”100” = 500 sec (OGNI VARIAZIONE DI UNA UNITA’ CORRISPONDE A 5 sec); 5. PREMENDO IL TASTO 12 SI OTTIENE LA MEMORIZZAZIONE DEL VALORE IMPOSTATO. RINNOVA NOX SETTAGGIO POSTCIRCOLAZIONE • Service PERMETTE DI REGOLARE IL TEMPO DI POSTCIRCOLAZIONE DELLA POMPA IN FUNZIONE RISCALDAMENTO – LA PROCEDURA PER VARIARE L’IMPOSTAZIONE PREVEDE: 1. 2. 3. 4. ENTRARE IN “MODALITA’ PROGRAMMAZIONE” PREMENDO CONTEMPORANEAMENTE I TASTI 12,13 E 14 FINO A FAR APPARIRE IL PARAMETRO “P01”; SCORRERE I PARAMETRI PREMENDO I TASTI 13 E 14 FINO A FAR APPARIRE SUL DISPLAY IL VALORE PARAMETRO “P11”; UTILIZZANDO I TASTI 10 E 11 E’ POSSIBILE VARIARE IL VALORE DEL PREMENDO. CON IL TASTO 12 SI OTTIENE LA MEMORIZZAZIONE DEL VALORE IMPOSTATO. RINNOVA NOX FUNZIONE PRERISCALDO 3 STELLE • Service FUNZIONE CHE PERMETTE DI AUMENTARE LE PRESTAZIONI DELLA CALDAIA IN SANITARIO. – SI ATTIVA LA FUNZIONE PREMENDO CONTEMPORANEAMENTE I TASTI 10 E 11 FINO A FARE APPARIRE SUL DISPLAY IL SIMBOLO – – LA FUNZIONE SI ATTIVA SE LA TEMPERATURA RILEVATA DALLA SONDA RISCALDAMENTO SCENDE AL DI SOTTO DELLA TEMPERATURA SANITARIO IMPOSTATA, ACCENDENDO LA CALDAIA IN SANITARIO ALLA MINIMA POTENZA; DURANTE IL FUNZIONAMENTO SANITARIO LA FUNZIONE PRERISCALDO E’ INIBITA. RINNOVA NOX COLLEGAMENTO SONDA ESTERNA Service – LA PROCEDURA PREVEDE: – IL COLLEGAMENTO DELLA SONDA ESTERNA AI MORSETTI IN E1 ED E2; – UTILIZZARE CABLAGGI CON SEZIONE NON INFERIORE A 0,5 mm2; – LUNGHEZZA MASSIMA CABLAGGIO NON OLTRE I 20mt., POSSIBILMENTE SU CANALINE DIVERSE SU QUELLE IN TENSIONE DI RETE (230). Sonda esterna: NTC 10KOhm = 25°C RINNOVA NOX ABILITAZIONE SONDA ESTERNA Service • PERMETTE LA REGOLAZIONE DELLA TEMPERATURA DI MANDATA RISCALDAMENTO IN FUNZIONE DELLA TEMPERATURA ESTERNA – LA PROCEDURA DI CONFIGURAZIONE SONDA ESTERNA: – ENTRARE I “MODALITA’PROGRAMMAZIONE” E SCORRERE I PARAMETRI FINO A FAR APPARIRE SUL DISPLAY IL PARAMETRO “P15”; – UTILIZZANDO I TASTI 10 e 11 E’ POSSIBILE VARIARE IL VALORE DEL PARAMETRO 15 DA “00”--->”60” (IL VALORE IMPOSTATO CORRISPONDE AL VALORE DECIMALE DEL COEFFICIENTE “K”); – OO = SONDA ESTERNA NON PRESENTE – 60 = K6 – PREMENDO IL TASTO 12 PER MEMORIZZAZIONE IL VALORE IMPOSTATO. – A QUESTO PUNTO LA CALDAIA, RISPETTERA’ LA TEMPERATURA DI MANDATA IN FUNZIONE ALLA TEMPERATURA ESTERNA ED AL VALORE K IMPOSTATO. RINNOVA NOX REGOLAZIONE TEMP. SONDA ESTERNA Service – SE LA TEMPERATURA AMBIENTE NON E’ SODDISFACIENTE, IL CLIENTE HA LA POSSIBILITA’ DI VARIARE LA TEMPERATURA DI MANDATA RISCALDAMENTO DI ± 15°C DIRETTAMENTE IN CALDAIA TRAMITE I TSTI 13 E 14 SENZA VARIARE LA CURVA KLIMATICA. RINNOVA NOX Service Logica di funzionamento LOGICA DI FUNZIONAMENTO (STD CON PRESS. ASSOLUTO E PRESS. FUMI) Service DISPLAY 1 RICHIESTA: RISC. SAN. ANTIGELO PRERISC. 2 POMPA 3 PRESENZA ACQUA (TRASDUTTORE DI PRESSIONE) NOTE LINEA T.A = 0 Vac LAMPEGGIANTE F.SAN = 0 Vcc LAMPEGGIANTE NTC RISC. < 5° C NTC RISC. 230 Vac SEGNALE DI PRESSIONE = PRESSIONE NOMINALE OK VAI A 4 SEGNALE DI PRESSIONE <0,3bar O SENSORE STACCATO O SENSORE IN CORTO POMPA OFF SEGNALAZIONE ERRORE RINNOVA NOX LOGICA DI FUNZIONAMENTO (STD CON PRESS. ASSOLUTO E PRESS. FUMI) Service DISPLAY 4 5 VALVOLA DEVIATRICE VERIFICA SENSORI NOTE RICH. RISC. 230 Vac CELESTE-NERO RICH. SAN. 230 Vac CELESTE-MARRONE NTC RISC. NO RISC. NO SAN. CALDAIA FERMA NTC SAN. OK RISC. OK SAN. OK VAI A 6 TERM. MASSIMA NO RISC. NO SAN. CALDAIA FERMA SONDA ESTERNA OK RISC. (POTEN. RISC.) OK SAN. RINNOVA NOX LOGICA DI FUNZIONAMENTO (STD CON PRESS. ASSOLUTO E PRESS. FUMI) Service DISPLAY 6 VERIFICA PRESSOSTATO FUMI COM – NO = 5 Vcc NOTE OK VAI A 7 CONTATTO APERTO COM – NO = 0 Vcc CONTATTO CHIUSO 7 ALIMENTAZIONE VENTILATORE 8 VERIFICA PRESSOSTATO FUMI VENTILATORE NON ALIMENTATO CALDAIA FERMA 230 Vac COM – NO = 0 Vcc OK VAI A 9 CONTATTO CHIUSO COM – NO = 5 Vcc VENTILATORE ALIMENTATO CONTATTO APERTO 9 SCARICHE RINNOVA NOX LOGICA DI FUNZIONAMENTO (STD CON PRESS. ASSOLUTO E PRESS. FUMI) Service DISPLAY 10 VALVOLA GAS SCARICA 11 IONIZZAZIONE 12 VERIFICA CIRCOLAZIONE ACQUA NTC RISC. (PRESS. ASSOLUTO) NOTE 230 Vac SI OK VAI A 12 NO 3 TENTATIVI MULTIPLI DI RIACCENSIONE CALDAIA FERMA INCREMENTO TEMP. < 6,5°/SEC OK VAI AL 13 INCREMENTO TEMP. > 6,5°/SEC 5 TENTATIVI DI RIACCENSIONE (T < 43°C) CALDAIA FERMA 13 MODULAZIONE RINNOVA NOX