Service PARVA Recupera IDRAULICA CIRCUITO IDRAULICO Service FUNZIONAMENTO IN RISCALDAMENTO Parva Recupera - Idraulica VASO DI ESPANSIONE • • Service COMPITO – COMPENSA L’AUMENTO DI PRESSIONE DETERMINATO DALL’AUMENTO DI TEMPERATURA DELL’ACQUA NELL’IMPIANTO DI RISCALDAMENTO DATI – CAPACITA’ TOTALE 7,0 LITRI – CAPACITA’ UTILE 3,5 LITRI – PRESSIONE DI PRECARICA 1 bar – CONTENUTO MASSIMO D’ ACQUA NELL’IMPIANTO 109 LITRI (85°C) Parva Recupera - Idraulica SCAMBIATORE PRIMARIO • Service SCAMBIATORE PRIMARIO – HA IL COMPITO DI TRASFERIRE IL CALORE DELLA COMBUSTIONE DEL GAS ALL’ACQUA CHE LO ATTRAVERSA – BREVETTO BSG – REALIZZATO IN RAME – BASSE PERDITE DI CARICO DOVUTA ALLA GEOMETRIA DEGLI ATTACCHI E DEI COLLETTORI – COMPOSTO DA 8 TUBI OVALIZZATI – TURBOLATORI INTERNI – MODELLI: – 24 KW – 28 KW – SPECIFICO PER CALDAIA PARVA Recupera Parva Recupera - Idraulica RECUPERATORE DI CALORE • Service RECUPERATORE DI CALORE – HA IL COMPITO DI RECUPERARE IL CALORE RESIDUO DEI FUMI PRODOTTI DELLA COMBUSTIONE E TRASFERIRLO ALL’ACQUA CHE LO ATTRAVERSA (FUNZIONE DI PRERISCALDO) – I FUMI VENGONO IMMESSI IN ATMOSFERA A TEMPERATURA INFERIORI E IL LORO CALORE LATENTE SFRUTTATO ANZICHE DISPERSO. – PROGETTO E SVILUPPO BSG – REALIZZATO IN ALLUMINIO PRESSOFUSO TEFLONATO – TALE RIVESTIMENTO GARANTISCE LA PROTEZIONE CONTRO L’ACIDITA’ DELLA CONDENSA – POSIZIONATO NELLA PARTE SUPERIORE DELLA CAMERA DI COMBUSTIONE. GARANTISCE: – ACCESSIBILITA’ – FACILITA’ DI PULIZIA e/o MANUTENZIONE Parva Recupera - Idraulica RECUPERATORE DI CALORE • Service RECUPERATORE DI CALORE – COSTITUITO DA: – CORPO CENTRALE – RACCORDI IDRAULICI TENUTA OR – ATTACCO VENTILATORE – BACINELLA INFERIORE – TENUTA CON GUARNIZIONE E VITI DI FISSAGGI – RACCORDO SCARICO CONDENSA – COPERCHIO SUPERIORE – TENUTA CON GUARNIZIONE E VITI DI FISSAGGI – INNESTO PER SONDA FUMI – CONVOGLIATORE INTERNO DEI FUMI – SERPENTINO INTERNO ALETTATO – REALIZZATO A SPIRALE – LA GEOMETRIA DEL SERPENTINO PERMETTE DI RECUPERARE IL CALORE DEI FUMI E TRASFERILO ALL’ACQUA CHE CIRCOLA AL SUO INTERNO – ALTA SUPERFICIE DI SCAMBIO > ALTO RENDIMENTO Parva Recupera - Idraulica RECUPERATORE DI CALORE • Service RECUPERATORE DI CALORE – DISPOSITIVO INTERNO PER IL BLOCCO DELLA CONDENSA – DISPOSITIVO DI SICUREZZA CHE BLOCCA IL FUNZIONAMENTO DELLA CALDAIA QUALORA LO SCARICO CONDENSA FOSSE OSTRUITO – LA CONDENSA RISALENDO OSTRUISCE L’EVACUAZIONE DEI FUMI ATTRAVERSO IL CANALE DA FUMO FACENDO INTERVENIRE IL TRASDUTTORE DI PRESSIONE – SENSORE FUMI POSIZIONATO NELLA PARTE SUPERIORE SCARICO FUMI SONDA FUMI MANDATA ALL’IMPIANTO RITORNO ALL’IMPIANTO ATTACCO VENTILATORE Parva Recupera - Idraulica COMPONENTISTICA • Service SCAMBIO TERMICO PERMETTE DI RECUPERARE PARTE DEL CALORE CHE ALTRIMENTI ANDREBBE DISPERSO IN ATMOSFERA E CEDERLO ALL’ACQUA “FREDDA” DEL RITORNO RISC. L’ACQUA PRERISCALDATA VIENE PORTATA E MANTENUTA IN TEMPERATURA DALLA COMBUSTIONE DEI GAS Parva Recupera - Idraulica SIFONE SCARICO CONDENSA • • Service SIFONE SCARICO CONDENSA HA IL COMPITO DI EVACUARE LA CONDENSA PRODOTTA NEL RECUPERATORE FUMI PORTANDOLA ALL’ESTERNO DELLA CALDAIA – LO SCARICO CONDENSA E’ COMPOSTO DA: – TUBAZIONE DI RACCORDO TRA RECUPERATORE E SIFONE – SIFONE SCARICO CONDENSA – POSTO NELLA PARTE INFERIORE DX DELLA CALDAIA – VERIFICABILE – CON GALLEGGIANTE INTERNO – COMPONENTE DI SICUREZZA CHE EVITA L’EVENTUALE FUORIUSCITA DI FUMI IN AMBIENTE QUALORA NON VI SIA CONDENSA NEL SIFONE – QUALORA LO SCARICO CONDENSA FOSSE OSTRUITO LA CONDENSA RISALE ATTRAVERSO IL CONDOTTO RAGGIUNGENDO IL RECUPERATORE FUMI PROVOCANDO L’INTERVENTO DEL TRASDUTTORE DI PRESSIONE. – LA CONDENSA PUO’ ESSERE SCARICATA IN FOGNATURA (rif. UNI 11071) Parva Recupera - Idraulica POMPA • • • Service COMPITO – IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO – IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO CARATTERISTICHE – COMPATTO – DISAREATORE INCORPORATO DATI – MODELLO WILO WHITE GOOD 12/5 – ALIMENTATO A 230 Vc.a. – PREVALENZA RESIDUA SUPERIORE 3 M.C.A ALLA PORTATA DI 1000 l/h A Parva Recupera - Idraulica GRUPPO ACQUA • Service GRUPPO ACQUA IN PLASTICA – BREVETTO BSG – OLTRE 20 ANNI DI ESPERIENZA SUI MATERIALI PLASTICI – ALTE TEMPERATURA DI LAVORO (130°C) – DI FACILE ACCESSO E SEMPLICE MANUTENZIONE – STESSE CONNESSIONI IDRAULICHE DEI MODELLI PRECEDENTI Parva Recupera - Idraulica GRUPPO DI MANDATA RISC+SAN • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – VALVOLA TRE VIE – PRESSOSTATO PRIMARIO – BY-PASS – NTC SANITARIO Service PRESSOSTATO CIRCUITO PRIAMRIO NTC ACS BY PASS USCITA ACS MANDATA RISCALDAMENTO OTTURATORE 3 VIE M0OTORE 3 VIE Parva Recupera - Idraulica GRUPPO DI MANDATA SV • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – VALVOLA TRE VIE – PRESSOSTATO PRIMARIO – BY-PASS MANDATA RISCALDAMENTO Service BY PASS PRESSOSTATO CIRCUITO PRIMARIO MANDATA SERPENTINO BOLLITORE OTTURATORE 3 VIE MOTORE 3 VIE Parva Recupera - Idraulica GRUPPO MANDATA – VALVOLA TRE VIE • Service VALVOLA TRE VIE – IL COMPITO E’ DI DEVIARE IL FLUSSO DELL’ACQUA CHE ESCE DALLO SCAMBIATORE PRIMARIO VERSO L’IMPIANTO DI RISCALDAMENTO O VERSO LO SCAMBIATORE SANITARIO – COMPOSTA DA: • MOTORE BITRON “COMPATTO”: CORSA 10 mm • GRUPPO OTTURATORI (SENZA MOTORE POSIZIONE A RIPOSO IN RISCALDAMENTO) – COMMUTA IN RISCALDAMENTO SOLO QUANDO T.A. CHIUDE CONTATTO – FINE CORSA INTERNO PER EVITARE SOVRACCARICO DEL MOTORE – ALIMENTAZIONE 220Vac ALLO SCAMBIATORE A PIASTRE – RESISTENZA ELETTRICA MOTORE 8,30 Kohm – POSIZIONATO FRONTALMENTE • FACILITATA L’ACCESSIBILITA’ e DIMENSIONI PIU’ COMPATTE RICAMBI 2 OTTURATORI DIVERSI: • BI 1351109 fino a 09-12 • BI 1491101 da 10-12 DALLO SCAMBIATORE PRIMARIO ALLA MANDATA RISCALDAMENTO Parva Recupera - Idraulica MOTORE VALVOLA 3 VIE Service • TENSIONE AL MOTORE 3 VIE CON NUOVO GRUPPO IN MATERIALE COMPOSITO SANITARIO RISCALDAMENTO Parva Recupera - Idraulica EVOLUZIONE VALVOLA TRE VIE Service MODELLI DI CALDAIE IN PRODUZIONE M96A…SM/BD M96A…SV/BD CALDAIE IN PRODUZIONE FINO A 02-12 M96A…SM/BDY M96A…SV/BDY RICAMBI VALIDI FINO A 09-12 M96A…SM/BDY M96A…SV/BDY RICAMBI VALIDI DA 10-12 Parva Recupera - Idraulica EVOLUZIONE VALVOLA TRE VIE • Service IL PARAMETRO PM13 DECIDE LA POSIZIONE DI LAVORO DELLA VALVOLA TRE VIE • PARAMETRO 13 = 7 GRUPPO IN PLASTICA E MOTORE ALIMENTATO CON CABLAGGIO A TRE CONNETTORI • PARAMETRO 13 = 1 TUTTI GLI ALTRI CASI P13 = 7 P13 = 1 Parva Recupera - Idraulica PRESSOSTATO RISCALDAMENTO • COMPITO – VERIFICARE SOLO PRESENZA ACQUA NEL CIRCUITO PRIMARIO NON VERIFICA LA CIRCOLAZIONE • CARATTERISTICHE – PRESSIONE DI INTERVENTO MIN. 0,35 mbar (ABBINABILE AD IMPIANTI A VASO APERTO) – COLLEGAMENTO A 2 FILI (COM-NO) – 24 Vdc – DIGNOSTICA SPECIFICA (E04 INDICA SOLO SCARSA PRESSIONE E NON LA MANCATA CIRCOLAZIONE ACQUA) Service Parva Recupera - Idraulica BY PASS • • Service COMPITO – GARANTISCE UNA MINIMA PORTATA ALLO SCAMBIATORE PRIMARIO A PRESCINDERE DALLE CONDIZIONI IDRAULICHE DELL’IMPIANTO CARATTERISTICHE – AUTOMATICO E NON TARABILE – UNICO MODELLO PER LE VARIE POTENZE NTC SANITARIO • • COMPITO – VERIFICA TEMPERATURA ACS CARATTERISTICHE – 5 V DCV – TENUTA IDRAULICA CON OR + FORCINA – IN CASO DI GUASTO TUTTE LE FUNZIONI DELL’APPARECCHIO SONO ATTIVE Parva Recupera - Idraulica NTC RISCALDAMENTO • • Service COMPITO – MONITORARE LA TEMPERATURA DEL CIRCUITO PRIMARIO PER: • GESTIRE LA MODULAZIONE IN BASE ALLA TEMPERATURA RAGGIUNTA • VERIFICARE LA CIRCOLAZIONE ACQUA PRIMARIA ATTRAVERSO LA VELOCITA DI VARIAZIONE DELLA TEMPERATURA CARATTERISTICHE – INSTALLATO SUL TUBO D’ USCITA DALLO SCAMBIATORE PRIMARIO – STESSO BETA DEGLI ALTRI NTC – PER QUALSIASI GUASTO A QUESTA SONDA IL BRUCIATORE NON SI ACCENDE PER NESSUNA RICHIESTA Parva Recupera - Idraulica CIRCUITO IDRAULICO Service FUNZIONAMENTO IN SANITARIO Parva Recupera - Idraulica GRUPPO DI RITORNO Service FLUSSIMETRO SANITARIO • • RUBINETTO DI SCARICO CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – FLUSSIMETRO SANITARIO – RUBINETTO DI CARICO – VALVOLA 3 bar – RUBINETTI DI SCARICO ENTRATA SANITARIO SENSORE FLUSSIMETRO RITORNO RISCALDAMENTO RUBINETTO DI CARICO Parva Recupera - Idraulica FLUSSIMETRO SANITARIO Service • COMPITO – DISPOSITIVO CHE INVIA UN SEGNALE ELETTRICO (AL CIRCUITO ELETTRONICO DI CONTROLLO) PROPORZIONALE ALLA QUANITA’ D’ACQUA PRELEVATA AD USO SANITARIO. • CARATTERISTICHE – GALLEGGIANTE CON MAGNETE A TURBINA POSIZIONATO IN VERTICALE – GALLEGGIANTE INTERAMENTE REALIZZATO IN MATERIALE PLASTICO PER EVITARE PROBLEMI DI CORROSIONE – CONTATTO ELETTRICO 5Vcc – FACILITA’ DI MANUTENZIONE – FILTRO ACQUA IN INGRESSO – PORTATA MINIMA 2,0L/min Parva Recupera - Idraulica GRUPPO DI RITORNO (fuori produzione da 02-12) • • CARATTERISTICHE – MATERIALE COMPOSITO – ACCESSO E MANUTENZIONI FACILITATE COMPONENTI ASSEMBLATI – FLUSSOSTATO SANITARIO – RUBINETTO DI CARICO – VALVOLA 3 bar – RUBINETTI DI SCARICO Service RUBINETTO DI SCARICO RUBINETTO DI CARICO FLUSSOSTATO SANITARIO ENTRATA SANITARIO RITORNO RISCALDAMENTO Parva Recupera - Idraulica CONFIGURAZIONE PARAMETRO 25 • Service IL PARAMETRO PM 25 DECIDE LA TIPOLOGIA DI FLUSSOSTATO SANITARIO INSTALLATO IN CALDAIA • P25 = 1 FLUSSOSTATO • P25 = 7 FLUSSIMETRO P25 = 1 P25 = 7 Parva Recupera - Idraulica SCAMBIATORE SANITARIO Service COMPITO • PRODURRE ACQUA CALDA SANITARIA ATTRAVERSO UNO SCAMBIO TERMICO ACQUA ACQUA CARATTERISTICHE • REALIZZATO CON PIASTRE IN ACCIAIO • GEOMETRIA A NIDO D’APE • SUPERFICI DI SCAMBIO PER GARANTIRE ELEVATA EFFICIENZA • FLUSSI DEI CIRCUITI IN CONTROCORRENTE MODELLO 24 S 28 S N° PIASTRE 14 14 PORTATA l/min DT 25° 16 20 Parva Recupera - Idraulica