Service
PARVA Recupera
IDRAULICA
CIRCUITO IDRAULICO
Service
FUNZIONAMENTO IN
RISCALDAMENTO
Parva Recupera - Idraulica
VASO DI ESPANSIONE
•
•
Service
COMPITO
– COMPENSA L’AUMENTO DI
PRESSIONE DETERMINATO
DALL’AUMENTO DI TEMPERATURA
DELL’ACQUA NELL’IMPIANTO DI
RISCALDAMENTO
DATI
– CAPACITA’ TOTALE 7,0 LITRI
– CAPACITA’ UTILE 3,5 LITRI
– PRESSIONE DI PRECARICA 1 bar
– CONTENUTO MASSIMO D’ ACQUA
NELL’IMPIANTO 109 LITRI (85°C)
Parva Recupera - Idraulica
SCAMBIATORE PRIMARIO
•
Service
SCAMBIATORE PRIMARIO
– HA IL COMPITO DI TRASFERIRE IL CALORE DELLA COMBUSTIONE DEL GAS
ALL’ACQUA CHE LO ATTRAVERSA
– BREVETTO BSG
– REALIZZATO IN RAME
– BASSE PERDITE DI CARICO DOVUTA ALLA GEOMETRIA DEGLI ATTACCHI E DEI
COLLETTORI
– COMPOSTO DA 8 TUBI OVALIZZATI
– TURBOLATORI INTERNI
– MODELLI:
– 24 KW
– 28 KW
– SPECIFICO PER CALDAIA PARVA Recupera
Parva Recupera - Idraulica
RECUPERATORE DI CALORE
•
Service
RECUPERATORE DI CALORE
– HA IL COMPITO DI RECUPERARE IL CALORE RESIDUO DEI FUMI PRODOTTI DELLA
COMBUSTIONE E TRASFERIRLO ALL’ACQUA CHE LO ATTRAVERSA (FUNZIONE DI
PRERISCALDO)
– I FUMI VENGONO IMMESSI IN ATMOSFERA A TEMPERATURA INFERIORI E IL
LORO CALORE LATENTE SFRUTTATO ANZICHE DISPERSO.
– PROGETTO E SVILUPPO BSG
– REALIZZATO IN ALLUMINIO PRESSOFUSO TEFLONATO
– TALE RIVESTIMENTO GARANTISCE LA PROTEZIONE
CONTRO
L’ACIDITA’ DELLA CONDENSA
– POSIZIONATO NELLA PARTE SUPERIORE DELLA CAMERA
DI
COMBUSTIONE. GARANTISCE:
– ACCESSIBILITA’
– FACILITA’ DI PULIZIA e/o MANUTENZIONE
Parva Recupera - Idraulica
RECUPERATORE DI CALORE
•
Service
RECUPERATORE DI CALORE
– COSTITUITO DA:
– CORPO CENTRALE
– RACCORDI IDRAULICI TENUTA OR
– ATTACCO VENTILATORE
– BACINELLA INFERIORE
– TENUTA CON GUARNIZIONE E VITI DI FISSAGGI
– RACCORDO SCARICO CONDENSA
– COPERCHIO SUPERIORE
– TENUTA CON GUARNIZIONE E VITI DI FISSAGGI
– INNESTO PER SONDA FUMI
– CONVOGLIATORE INTERNO DEI FUMI
– SERPENTINO INTERNO ALETTATO
– REALIZZATO A SPIRALE
– LA GEOMETRIA DEL SERPENTINO PERMETTE DI RECUPERARE IL CALORE
DEI FUMI E TRASFERILO ALL’ACQUA CHE CIRCOLA AL SUO INTERNO
– ALTA SUPERFICIE DI SCAMBIO > ALTO RENDIMENTO
Parva Recupera - Idraulica
RECUPERATORE DI CALORE
•
Service
RECUPERATORE DI CALORE
– DISPOSITIVO INTERNO PER IL BLOCCO DELLA CONDENSA
– DISPOSITIVO DI SICUREZZA CHE BLOCCA IL FUNZIONAMENTO DELLA CALDAIA
QUALORA LO SCARICO CONDENSA FOSSE OSTRUITO
– LA CONDENSA RISALENDO OSTRUISCE L’EVACUAZIONE DEI FUMI
ATTRAVERSO IL CANALE DA FUMO FACENDO INTERVENIRE IL TRASDUTTORE
DI PRESSIONE
– SENSORE FUMI POSIZIONATO NELLA PARTE SUPERIORE
SCARICO FUMI
SONDA FUMI
MANDATA
ALL’IMPIANTO
RITORNO
ALL’IMPIANTO
ATTACCO
VENTILATORE
Parva Recupera - Idraulica
COMPONENTISTICA
•
Service
SCAMBIO TERMICO
PERMETTE DI RECUPERARE PARTE DEL
CALORE CHE ALTRIMENTI ANDREBBE
DISPERSO IN ATMOSFERA E CEDERLO
ALL’ACQUA “FREDDA” DEL RITORNO RISC.
L’ACQUA PRERISCALDATA VIENE
PORTATA E MANTENUTA IN
TEMPERATURA DALLA COMBUSTIONE DEI
GAS
Parva Recupera - Idraulica
SIFONE SCARICO CONDENSA
•
•
Service
SIFONE SCARICO CONDENSA
HA IL COMPITO DI EVACUARE LA CONDENSA PRODOTTA NEL RECUPERATORE FUMI
PORTANDOLA ALL’ESTERNO DELLA CALDAIA
– LO SCARICO CONDENSA E’ COMPOSTO DA:
– TUBAZIONE DI RACCORDO TRA RECUPERATORE E SIFONE
– SIFONE SCARICO CONDENSA
– POSTO NELLA PARTE INFERIORE DX DELLA CALDAIA
– VERIFICABILE
– CON GALLEGGIANTE INTERNO
– COMPONENTE DI SICUREZZA CHE EVITA L’EVENTUALE FUORIUSCITA
DI FUMI IN AMBIENTE QUALORA NON VI SIA CONDENSA NEL SIFONE
– QUALORA LO SCARICO CONDENSA FOSSE OSTRUITO LA CONDENSA RISALE
ATTRAVERSO IL CONDOTTO RAGGIUNGENDO IL RECUPERATORE FUMI
PROVOCANDO L’INTERVENTO DEL TRASDUTTORE DI PRESSIONE.
– LA CONDENSA PUO’ ESSERE SCARICATA IN FOGNATURA (rif. UNI 11071)
Parva Recupera - Idraulica
POMPA
•
•
•
Service
COMPITO
– IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO
– IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO
CARATTERISTICHE
– COMPATTO
– DISAREATORE INCORPORATO
DATI
– MODELLO WILO WHITE GOOD 12/5
– ALIMENTATO A 230 Vc.a.
– PREVALENZA RESIDUA SUPERIORE
3 M.C.A ALLA PORTATA DI 1000 l/h
A
Parva Recupera - Idraulica
GRUPPO ACQUA
•
Service
GRUPPO ACQUA IN PLASTICA
– BREVETTO BSG
– OLTRE 20 ANNI DI ESPERIENZA SUI MATERIALI PLASTICI
– ALTE TEMPERATURA DI LAVORO (130°C)
– DI FACILE ACCESSO E SEMPLICE MANUTENZIONE
– STESSE CONNESSIONI IDRAULICHE DEI MODELLI PRECEDENTI
Parva Recupera - Idraulica
GRUPPO DI MANDATA RISC+SAN
•
•
CARATTERISTICHE
– MATERIALE COMPOSITO
– ACCESSO E MANUTENZIONI FACILITATE
COMPONENTI ASSEMBLATI
– VALVOLA TRE VIE
– PRESSOSTATO PRIMARIO
– BY-PASS
– NTC SANITARIO
Service
PRESSOSTATO
CIRCUITO
PRIAMRIO
NTC ACS
BY PASS
USCITA ACS
MANDATA
RISCALDAMENTO
OTTURATORE 3 VIE
M0OTORE 3 VIE
Parva Recupera - Idraulica
GRUPPO DI MANDATA SV
•
•
CARATTERISTICHE
– MATERIALE COMPOSITO
– ACCESSO E MANUTENZIONI FACILITATE
COMPONENTI ASSEMBLATI
– VALVOLA TRE VIE
– PRESSOSTATO PRIMARIO
– BY-PASS
MANDATA
RISCALDAMENTO
Service
BY PASS
PRESSOSTATO
CIRCUITO
PRIMARIO
MANDATA
SERPENTINO
BOLLITORE
OTTURATORE 3 VIE
MOTORE 3 VIE
Parva Recupera - Idraulica
GRUPPO MANDATA – VALVOLA TRE VIE
•
Service
VALVOLA TRE VIE
– IL COMPITO E’ DI DEVIARE IL FLUSSO DELL’ACQUA CHE ESCE DALLO SCAMBIATORE
PRIMARIO VERSO L’IMPIANTO DI RISCALDAMENTO O VERSO LO SCAMBIATORE SANITARIO
–
COMPOSTA DA:
• MOTORE BITRON “COMPATTO”: CORSA 10 mm
• GRUPPO OTTURATORI (SENZA MOTORE POSIZIONE A RIPOSO IN RISCALDAMENTO)
– COMMUTA IN RISCALDAMENTO SOLO QUANDO T.A. CHIUDE CONTATTO
– FINE CORSA INTERNO PER EVITARE SOVRACCARICO DEL MOTORE
– ALIMENTAZIONE 220Vac
ALLO SCAMBIATORE A
PIASTRE
– RESISTENZA ELETTRICA MOTORE 8,30 Kohm
– POSIZIONATO FRONTALMENTE
• FACILITATA L’ACCESSIBILITA’ e DIMENSIONI PIU’ COMPATTE
RICAMBI
2 OTTURATORI DIVERSI:
•
BI 1351109 fino a 09-12
•
BI 1491101 da 10-12
DALLO
SCAMBIATORE
PRIMARIO
ALLA MANDATA
RISCALDAMENTO
Parva Recupera - Idraulica
MOTORE VALVOLA 3 VIE
Service
• TENSIONE AL MOTORE 3 VIE CON NUOVO GRUPPO IN MATERIALE
COMPOSITO
SANITARIO
RISCALDAMENTO
Parva Recupera - Idraulica
EVOLUZIONE VALVOLA TRE VIE
Service
MODELLI DI
CALDAIE
IN PRODUZIONE
M96A…SM/BD
M96A…SV/BD
CALDAIE IN PRODUZIONE
FINO A 02-12
M96A…SM/BDY
M96A…SV/BDY
RICAMBI VALIDI FINO A 09-12
M96A…SM/BDY
M96A…SV/BDY
RICAMBI VALIDI DA 10-12
Parva Recupera - Idraulica
EVOLUZIONE VALVOLA TRE VIE
•
Service
IL PARAMETRO PM13 DECIDE LA POSIZIONE DI LAVORO DELLA VALVOLA TRE VIE
• PARAMETRO 13 = 7 GRUPPO IN PLASTICA E MOTORE ALIMENTATO CON
CABLAGGIO A TRE CONNETTORI
• PARAMETRO 13 = 1 TUTTI GLI ALTRI CASI
P13 = 7
P13 = 1
Parva Recupera - Idraulica
PRESSOSTATO RISCALDAMENTO
•
COMPITO
– VERIFICARE SOLO PRESENZA ACQUA NEL
CIRCUITO PRIMARIO NON VERIFICA LA
CIRCOLAZIONE
•
CARATTERISTICHE
– PRESSIONE DI INTERVENTO MIN. 0,35 mbar
(ABBINABILE AD IMPIANTI A VASO APERTO)
– COLLEGAMENTO A 2 FILI (COM-NO)
– 24 Vdc
– DIGNOSTICA SPECIFICA (E04 INDICA SOLO SCARSA
PRESSIONE E NON LA MANCATA CIRCOLAZIONE
ACQUA)
Service
Parva Recupera - Idraulica
BY PASS
•
•
Service
COMPITO
– GARANTISCE UNA MINIMA PORTATA ALLO
SCAMBIATORE PRIMARIO A PRESCINDERE DALLE
CONDIZIONI IDRAULICHE DELL’IMPIANTO
CARATTERISTICHE
– AUTOMATICO E NON TARABILE
– UNICO MODELLO PER LE VARIE POTENZE
NTC SANITARIO
•
•
COMPITO
– VERIFICA TEMPERATURA ACS
CARATTERISTICHE
– 5 V DCV
– TENUTA IDRAULICA CON OR + FORCINA
– IN CASO DI GUASTO TUTTE LE FUNZIONI
DELL’APPARECCHIO SONO ATTIVE
Parva Recupera - Idraulica
NTC RISCALDAMENTO
•
•
Service
COMPITO
– MONITORARE LA TEMPERATURA DEL CIRCUITO
PRIMARIO PER:
• GESTIRE LA MODULAZIONE IN BASE ALLA
TEMPERATURA RAGGIUNTA
• VERIFICARE LA CIRCOLAZIONE ACQUA
PRIMARIA ATTRAVERSO LA VELOCITA DI
VARIAZIONE DELLA TEMPERATURA
CARATTERISTICHE
– INSTALLATO SUL TUBO D’ USCITA DALLO
SCAMBIATORE PRIMARIO
– STESSO BETA DEGLI ALTRI NTC
– PER QUALSIASI GUASTO A QUESTA SONDA IL
BRUCIATORE NON SI ACCENDE PER NESSUNA
RICHIESTA
Parva Recupera - Idraulica
CIRCUITO IDRAULICO
Service
FUNZIONAMENTO IN
SANITARIO
Parva Recupera - Idraulica
GRUPPO DI RITORNO
Service
FLUSSIMETRO
SANITARIO
•
•
RUBINETTO
DI SCARICO
CARATTERISTICHE
– MATERIALE COMPOSITO
– ACCESSO E MANUTENZIONI
FACILITATE
COMPONENTI ASSEMBLATI
– FLUSSIMETRO SANITARIO
– RUBINETTO DI CARICO
– VALVOLA 3 bar
– RUBINETTI DI SCARICO
ENTRATA
SANITARIO
SENSORE
FLUSSIMETRO
RITORNO
RISCALDAMENTO
RUBINETTO DI
CARICO
Parva Recupera - Idraulica
FLUSSIMETRO SANITARIO
Service
• COMPITO
– DISPOSITIVO CHE INVIA UN SEGNALE
ELETTRICO (AL CIRCUITO
ELETTRONICO DI CONTROLLO)
PROPORZIONALE ALLA QUANITA’
D’ACQUA PRELEVATA AD USO
SANITARIO.
• CARATTERISTICHE
– GALLEGGIANTE CON MAGNETE A
TURBINA POSIZIONATO IN VERTICALE
– GALLEGGIANTE INTERAMENTE
REALIZZATO IN MATERIALE PLASTICO
PER EVITARE PROBLEMI DI
CORROSIONE
– CONTATTO ELETTRICO 5Vcc
– FACILITA’ DI MANUTENZIONE
– FILTRO ACQUA IN INGRESSO
– PORTATA MINIMA 2,0L/min
Parva Recupera - Idraulica
GRUPPO DI RITORNO (fuori produzione da 02-12)
•
•
CARATTERISTICHE
– MATERIALE COMPOSITO
– ACCESSO E MANUTENZIONI FACILITATE
COMPONENTI ASSEMBLATI
– FLUSSOSTATO SANITARIO
– RUBINETTO DI CARICO
– VALVOLA 3 bar
– RUBINETTI DI SCARICO
Service
RUBINETTO
DI SCARICO
RUBINETTO DI
CARICO
FLUSSOSTATO
SANITARIO
ENTRATA
SANITARIO
RITORNO
RISCALDAMENTO
Parva Recupera - Idraulica
CONFIGURAZIONE PARAMETRO 25
•
Service
IL PARAMETRO PM 25 DECIDE LA TIPOLOGIA DI FLUSSOSTATO SANITARIO INSTALLATO IN CALDAIA
• P25 = 1 FLUSSOSTATO
• P25 = 7 FLUSSIMETRO
P25 = 1
P25 = 7
Parva Recupera - Idraulica
SCAMBIATORE SANITARIO
Service
COMPITO
• PRODURRE ACQUA CALDA SANITARIA
ATTRAVERSO UNO SCAMBIO TERMICO ACQUA ACQUA
CARATTERISTICHE
• REALIZZATO CON PIASTRE IN ACCIAIO
• GEOMETRIA A NIDO D’APE
• SUPERFICI DI SCAMBIO PER GARANTIRE
ELEVATA EFFICIENZA
• FLUSSI DEI CIRCUITI IN CONTROCORRENTE
MODELLO
24 S
28 S
N° PIASTRE
14
14
PORTATA
l/min DT 25°
16
20
Parva Recupera - Idraulica
Scarica

Parva Recupera - Idraulica