Service
RinNOVA SOLAR TANK
IDRAULICA CALDAIA
CIRCUITO IDRAULICO
Service
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
POMPA
Service
•
COMPITO
– IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO
– IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO
•
CARATTERISTICHE
– COMPATTO
– DISAREATORE INCORPORATO
•
DATI
– MODELLO WILO INTNFSL 12/6 2 VELOCITA’
– ALIMENTATO A 230 Vc.a.
– GRADO DI PROTEZIONE IP44
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
SCAMBIATORE PRIMARIO E CONDENSANTE
•
•
•
COMPITO
– SCAMBIARE CALORE TRA
ACQUA PRIMARIA E
FIAMMA
– SCAMBIARE CALORE TRA
ACQUA PRIMARIA E FUMI
CARATTERISTICHE
– COSTRUITO CON
ELEMENTI IN ALLUMINIO
– ELEMENTI ALETTATI PER
AUMENTARE SCAMBIO
TERMICO ED
EVACQUAZIONE FUMI
– BRUCIATORE CENTRALE
DATI
– 25 KW : 2 ELEMENTI
– 35 KW : 3 ELEMENTI
Service
ALETTE DI SCAMBIO
TERMICO E
CONVOGLIAMENTO
FUMI
BRUCIATORE
INGRESSO
ACQUA
ALETTE DI SCAMBIO
TERMICO
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
SCAMBIATORE CONDENSANTE
Service
PRINCIPIO DI FUNZIONAMENTO:
I FUMI SONO CONVOGLIATI
AD ALTA VELOCITA’ VERSO
L’ALTO ATTRAVERSO I CANALI
CREATI DALLE ALETTE
SUPERIORI.
2.
I FUMI POI SONO SPINTI
VERSO IL BASSO ED IN
QUESTO PERCORSO
CEDONO IL LORO CALORE
ALL’ACQUA CHE CIRCOLA
NEL SENSO OPPOSTO
3.
PER FORZA DI GRAVITA LA
CONDENSA CHE SI CREA
ALL’INTERNO DELLO
SCAMBIATORE SCENDE
VERSO IL BASSO E PASSA
NEL SIFONE.
ACQUA
1.
PERCORSO
ACQUA
USCITA FUMI
PERCORSO FUMI
PROFILO GUIDA FUMI
(PERMETTE AI FUMI DI
ANDARE SOLO VERSO
L’ALTO)
SCARICO
CONDENSA
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
SCAMBIATORE CONDENSANTE
Service
CARATTERISTICHE
•
LE DIMENSIONI ED IL NUMERO DELLE
ALETTE PERMETTE A QUESTO
SCAMBIATORE DI AVERE UN OTTIMO
SCAMBIO TERMICO GRAZIE
ALL’ELEVATA SUPERFICIE DI
SCAMBIO
•
I PASSAGGI NEL LATO FUMI SONO
MOLTO RISTRETTI PER AUMENTARE
LA VELOCITA’ DEI FUMI STESSI
•
ACQUA E FUMI SEGUONO UN
PERCORSO IN CONTRCORRENTE:
L’ACQUA FREDDA SCAMBIA CON I
FUMI NEL PUNTO PIU’ BASSO IN
MODO DA FAVORIRE LA
CONDENSAZIONE
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
GRUPPO DI MANDATA SV
•
•
CARATTERISTICHE
– MATERIALE COMPOSITO
– ACCESSO E MANUTENZIONI FACILITATE
COMPONENTI ASSEMBLATI
– VALVOLA TRE VIE
– PRESSOSTATO PRIMARIO
– BY-PASS
MANDATA
RISCALDAMENTO
Service
BY PASS
TRASDUTTORE
PRESSIONE CIRCUITO
PRIMARIO
MANDATA
SMABIATORE
SANITARIO
ESTERNO
OTTURATORE 3 VIE
MOTORE 3 VIE
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
VALVOLA TRE VIE
•
COMPITO
– MODIFICARE IL CIRCUITO PRIMARIO IN
RELAZIONE AL TIPO DI RICHIESTA
(RISCALDAMENTO, SANITARIO/ANTIGELO)
•
CARATTERISTICHE
– COMPOSTO DA:
• NUOVO MOTORE (PISTONCINO CON CORSA
PIU’ LUNGA) 220 V, 9,35 KOHM
• NUOVO OTTURATORE (SENZA MOTORE
POSIZIONATO IN RISCALDAMENTO)
– POSIZIONE MOTORE A RIPOSO: SANITARIO
Service
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
MOTORE VALVOLA 3 VIE
Service
• TENSIONE AL MOTORE 3 VIE CON GRUPPO IN OTTONE
SANITARIO
RISCALDAMENTO
• TENSIONE AL MOTORE 3 VIE CON NUOVO GRUPPO IN MATERIALE
COMPOSITO
SANITARIO
RISCALDAMENTO
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
CIRCUITO IDRAULICO
Service
TRASDUTTORE DI PRESSIONE (NOVITA’ 2011)
– COMPONENTE DI SICUREZZA CHE VERIFICA LA PRESSIONE
DELL’ACQUA ALL’INTERNO DELLA CALDAIA E DELL’IMPIANTO
TERMICO. IL VALORE DI PRESSIONE VIENE TRADOTTO IN
SEGNALE ELETTRICO E VISUALIZZATO NEL LCD DELLA
CALDAIA.
• POSIZIONATO NELLA PARTE FRONTALE (FACILMENTE
ACCESSIBILE)
• COMPOSTO DA:
– CONNETTORE A TRE CONTATTI (5V-GND-OUT)
– MEMBRANA
– MOLLA
• COLLEGATO ELETTRICAMNETE ALLA SCHEDA INTEGRATA
– ALIMENTAZIONE ELETTRICA 24 Vdc
• PRESSIONE DI INTERVENTO 0,35 bar
• INCREMETATA LA SENSIBILITA’
• ABBINABILE AD IMPIANTI A VASO APERTO
• PERMETTE ALLA CALDAIA DI ATTIVARSI CON MINIME
PRESSIONI
• QUALORA IL VALORE DI PRESSIONE RILEVATO FOSSE
INFERIORE A 0,35 Bar: ANOMALIA SPECIFICA (E04)
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
NTC RISCALDAMENTO
•
•
Service
COMPITO
– MONITORARE LA TEMPERATURA DEL CIRCUITO
PRIMARIO PER:
• GESTIRE LA MODULAZIONE IN BASE ALLA
TEMPERATURA RAGGIUNTA
• VERIFICARE LA CIRCOLAZIONE ACQUA
PRIMARIA ATTRAVERSO LA VELOCITA DI
VARIAZIONE DELLA TEMPERATURA
CARATTERISTICHE
– INSTALLATO SUL TUBO D’ USCITA DALLO
SCAMBIATORE PRIMARIO
– STESSO BETA DEGLI ALTRI NTC
– PER QUALSIASI GUASTO A QUESTA SONDA IL
BRUCIATORE NON SI ACCENDE PER NESSUNA
RICHIESTA
RinNOVA SOLAR TANK- IDRAULICA CALDAIA
Scarica